U90 Ladder Software Manual
54
3. Select the parameters you wish to clear.
Clearing Jump conditions
To clear an existing Jump condition:
1. Right click on the Jump.
2. The Clear Jump icon appears.
3. Click the icon to clear the Jump.
Creating more than four Jumps for a Display
You can create up to 4 Jumps for each Display in the Display Editor. If you want to create
more than 4 Jumps for a Display, you must create the logic conditions in the Ladder Editor.
SI 2 contains the Current HMI Display number. You can jump to a specific Display by
writing the Display number into SI 2.
Example:
Writing #5 into SI 2 will cause Display #5 to be displayed on the controller.
Writing #8 into SI 2 will cause Display #8 to be displayed on the controller.
Take care to create the Displays as well as the logic conditions.
Display formats for MI and SI values